Therapy™ Dual-8™ Ablation Catheter
8 mm Tip Dual Thermocouple

Quadripolar
7 F

PRODUCT HIGHLIGHTS

  • Uni-directional steering
  • 8 mm tip electrode with two thermocouples
  • High power option up to 100 watts
  • Push/pull handle

ORDERING INFORMATION

Contents: 7 F ablation catheter (1 unit per box)


Reorder Number Description Electrode Spacing (mm) Tip Electrode (mm) Band Electrode (mm) Curve Type Usable Length (cm)
IBI-83371 1304-7-25-M-TE8TC2 2-5-2 8 2 Medium 110
IBI-83372 1304-7-25-L-TE8TC2 2-5-2 8 2 Large 110
IBI-83373 1304-7-25-XL-TE8TC2 2-5-2 8 2 X-Large 110
IBI-83374 1304-7-25-E-TE8TC2 2-5-2 8 2 Entended Reach 110
swipe-icon

Required Catheter Connecting Cables

swipe-icon
Therapy™ Dual-8™ Ablation Catheter 8 mm Tip Dual Thermocouple 

Rx Only

Brief Summary: Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

INDICATIONS

The Therapy™ Cardiac Ablation System is indicated for mapping and for use with a compatible RF generator for: interruption of accessory atrioventricular (AV) conduction pathways associated with tachycardia; the treatment of AV nodal re-entrant tachycardia (AVNRT); or creation of complete AV nodal block in patients with a difficult to control ventricular response to an atrial arrhythmia.

CONTRAINDICATIONS

In patients with active systemic infection. In patients with intracardiac mural thrombus, ventriculotomy or atriotomy within the preceding four weeks.

WARNINGS

Catheter ablation procedures present the potential for significant x-ray exposure. The long-term risk of protracted fluoroscopy has not been established. Careful consideration must be given for the use of the device in prepubescent children and pregnant women. The long term risks of RF ablation lesions have not been established. Patients undergoing AV nodal modification or ablation of septal accessory pathways are at risk for inadvertent AV block.

PRECAUTIONS

Appropriate DIP pads should be used to minimize skin burns.

POTENTIAL ADVERSE EVENTS

Potential adverse events include, but are not limited to, cardiovascular and anesthesia-related complications, including complete heart block requiring pacemaker. Please refer to the Instructions for Use for a complete list.

SJM-CAG-0915-0035t(1)

Last Updated: January 02, 2019

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

true
accessibility
© 2016 Abbott. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.

accessibility

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

Reorder Number Compatible Generator
IBI-85641 SJM
IBI-85739 Stockert