Family of LV Leads

Quartet™ Family of LV Leads

PRODUCT HIGHLIGHTS

  • MRI Ready lead tested in combination with MR Conditional devices for full-body scans using a 1.5 T (Tesla) field strength scanner*
  • Proven Quartet™ LV lead performance with additional Quadripolar lead options to match a patient’s anatomy
  • The Quartet™ Family of LV leads offers more distal shape options including the Large-S and Small-S as well as more total electrode spacing options including 40, 47 and 60 mm
  • Four unique pacing electrodes to provide more options and greater control in pacing vector selection
  • Superb deliverability with exceptional stability and performance
  • Low profile — 4.7 F lead body; 4.0 F lead tip
  • Optim™ lead insulation—a chemical co-polymer with proven strength and durability, demonstrating long-term abrasion resistance and biostability1,2
  • Steerable tip — distal tip angle can be controlled to maneuver through venous anatomy
  • Flexible lead body — narrow ring electrodes provide lead tip flexibility
  • Allows Direct-To-Target™ delivery placement through CPS Aim™ SL slittable inner catheter to deliver leads to small, acute venous anatomies that may have been unreachable in the past
  • Compatible with over-the-wire guidewire or stylet approaches

ORDERING INFORMATION

Left-heart lead


Reorder Number Shape Electrode Spacing (mm) Insulation Curve Lead Body (F) Connector Length (cm)
1458Q/75 Traditional S 47 Optim™ 16 4.7 IS4-LLLL 75
1458Q/86 Traditional S 47 Optim™ 16 4.7 IS4-LLLL 86
1458Q/92 Traditional S 47 Optim™ 16 4.7 IS4-LLLL 92
1456Q/75 Small-S 40 Optim™ 8 4.7 IS4-LLLL 75
1456Q/86 Small-S 40 Optim™ 8 4.7 IS4-LLLL 86
1457Q/75 Double Bend 47 Optim™ 16 4.7 IS4-LLLL 75
1457Q/86 Double Bend 47 Optim™ 16 4.7 IS4-LLLL 86
1458QL/75 Traditional S 47 Optim™ 16 4.7 IS4-LLLL 75
1458QL/86 Traditional S 60 Optim™ 16 4.7 IS4-LLLL 86
swipe-icon

*For additional information about specific MR conditional device and lead model numbers, including warnings, precautions, adverse conditions to MRI scanning, and potential adverse events please refer to Abbott’s MRI Ready Systems Manual at manuals.sjm.com.

1. Hayes, D., Freedman, R., Porterfield, J.G., Porterfield, L.M., Dinerman, J., Styperek, R.,Machell, C., Kim, G., Curtis A.B. (2015). Absence of externalized conductors and electricaldysfunction in Durata leads: results from a prospective, multicenter study [abstract]. Presented at Heart Rhythm 2015. Boston, Massachusetts.

2. Wilkoff, B. L., Rickard, J., Tkatchouk, E., Padsalgikar, A. D., Gallagher, G., and Runt, J. (2015).The biostability of cardiac lead insulation materials as assessed from long-term humanimplants. Journal of Biomedical Materials Research Part B: Applied Biomaterials.,104(2), 411–421.


Rx Only

 

Brief Summary: Prior to using these devices, please review the User’s Manual for
a complete listing of indications, contraindications, warnings, precautions, potential
adverse events and directions for use.

 

Indications and Usage: The Quartet lead has application as part of a St. Jude Medical™ biventricular system.

 

Contraindications: The use of the Quartet lead is contraindicated in patients who:

Are expected to be hypersensitive to a single dose of 1.0 mg of dexamethasone sodium phosphate.

Are unable to undergo an emergency thoracotomy procedure.

Have coronary venous vasculature that is inadequate for lead placement, as indicated by venogram.

SJM-QRT-0216-0025(5)

Last Updated: January 02, 2019

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

true
accessibility
© 2016 Abbott. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.

accessibility

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?