The new XIENCE Sierra Stent Design, with Slim Flex Technology, has a lower crossing profile1 and greater post-dilatation expansion
NEW STENT DELIVERY SYSTEM FOR COMPLEX CASES
Design innovations built to provide the flexibility, crossability, and pushability needed for even the most complex cases
1. Profile and expansion claims refer to XIENCE Alpine comparator.
SLIM
Lowest crossing profile of any DES on the market1
STRONG
Greatest longitudinal strength of any DES, best stent retention on the market, and robust radial strength1
PRECISE
100% accurate mid-marker placement with zero shortening for precise stent placement2
LARGE VESSELS
Post-dilatation up to 5.5mm3
Superior coating integrity, even at max expansion4
Zero shortening2
SIDE BRANCH ACCESS
Largest side branch access in workhorse sizes4
Stent design maintains integrity even when cell is opened4
RADIAL ACCESS
Unsurpassed pushability: Requires less force to cross lesions6
5 French compatible
Lowest crossing profile of any DES4
CTO
True Center Tip designed to succeed in CTOs4
Lowest crossing profile of any DES4
The only CTO-indicated stent
Proven safety in CTOs5
DIABETES
New long lengths for small vessels
Less force needed to cross tight lesions6
Proven superior safety and efficacy in diabetic patients7
1. Data on file at Abbott. Comparative claim refers to major drug-eluting stent manufacturers in U.S. market. Crossing profile refers to 3.0 mm diameter size.
2. Refers to 4.0 mm diameter expanded to 5.5 mm.
3. 5.5 mm maximum expansion in 3.5 and 4.0 mm diameter sizes.
4. Data on file at Abbott. Comparative claim refers to major drug-eluting stent manufacturers in U.S. market. Crossing profile refers to 3.0 mm diameter size.
5. EXPERT CTO Trial data demonstrated 1% definite stent thrombosis and 6.3% TLR at 1 year. Kandzari D, et al. “Safety and Effectiveness of Everolimus-Eluting Stents in Chronic Total Coronary Occlusion Revascularization.” JACC 2015.
6. Test performed by and data on file at Abbott. 3.0 mm diameter size tested, compared to XIENCE Alpine®, Synergy™, Resolute Onyx™.
7. Kaul, U., et al. Last Word on DES in Diabetics: Two Year TUXEDO Outcomes, TCT 2016. Tandjung, K; Clinical Outcome of Diabetic and Non-Diabetic Patients Treated With Second-Generation Zotarolimus-Eluting and Everolimus-Eluting DES: A Subgroup Analysis of the TWENTE Trial; TCT 2012. Superiority claim refers to Taxus.
PART NUMBERS AND ORDERING INFORMATION
STENT DIAMETER
LENGTH
POST-DILATATION LIMIT
8 mm
12 mm
15 mm
18 mm
2.25 mm
1550225-08
1550225-12
1550225-15
1550225-18
3.75 mm
2.5 mm
1550250-08
1550250-12
1550250-15
1550250-18
3.75 mm
2.75 mm
1550275-08
1550275-12
1550275-15
1550275-18
3.75 mm
3.0 mm
1550300-08
1550300-12
1550300-15
1550300-18
3.75 mm
3.25 mm
1550325-08
1550325-12
1550325-15
1550325-18
3.75 mm
3.5 mm
1550350-08
1550350-12
1550350-15
1550350-18
5.5 mm
4.0 mm
1550400-08
1550400-12
1550400-15
1550400-18
5.5 mm
New Sizes
STENT DIAMETER
LENGTH
POST-DILATATION LIMIT
23 mm
28 mm
33 mm
38 mm
2.25 mm
1550225-23
1550225-28
1550225-33
1550225-38
3.75 mm
2.5 mm
1550250-23
1550250-28
1550250-33
1550250-38
3.75 mm
2.75 mm
1550275-23
1550275-28
1550275-33
1550275-38
3.75 mm
3.0 mm
1550300-23
1550300-28
1550300-33
1550300-38
3.75 mm
3.25 mm
1550325-23
1550325-28
1550325-33
1550325-38
3.75 mm
3.5 mm
1550350-23
1550350-28
1550350-33
1550350-38
5.5 mm
4.0 mm
1550400-23
1550400-28
1550400-33
1550400-38
5.5 mm
PRODUCT INFO
Our online product catalogs provide the very latest information available, right at your fingertips. Download catalogs by product family in PDF format, or view the entire Abbott Vascular inventory in Excel. Product barcodes enable direct scanning for easy reordering.
Ensure that patients have information about coronary artery disease and the XIENCE family of stent systems. The XIENCE Patient Information Guide illustrates the stent procedure and outlines the risks and benefits of treatment with XIENCE.
The XIENCE V®, XIENCE nano®, XIENCE PRIME®, XIENCE PRIME® LL, XIENCE Xpedition®, XIENCE Xpedition® SV and XIENCE Xpedition® LL , XIENCE Alpine®, and XIENCE SierraTM (XIENCE Family) of Everolimus Eluting Coronary Stents on the MULTI-LINK VISION® or MULTI-LINK MINI VISION® Delivery System
INDICATIONS
The XIENCE Sierra stent system is indicated for improving coronary artery luminal diameter in patients, including those with diabetes mellitus, with symptomatic heart disease due to de novo native coronary artery lesions (length ≤ 32 mm) with reference vessel diameters of ≥ 2.25 mm to ≤ 4.25 mm. In addition, the XIENCE Sierra stent system is indicated for treating de novo chronic total coronary occlusions.
CONTRAINDICATIONS
The XIENCE Sierra stent system is contraindicated for use in:
Patients who cannot tolerate, including allergy or hypersensitivity to, procedural anticoagulation or the post-procedural antiplatelet regimen.
Patients with hypersensitivity or contraindication to everolimus or structurally related compounds, or known hypersensitivity to stent components (cobalt, chromium, nickel, tungsten, acrylic, fluoropolymers), or with contrast sensitivity.
WARNINGS
It is not recommended to treat patients having a lesion that prevent complete inflation of an angioplasty balloon.
Judicious patient selection is necessary because the use of this device carries the associated risk of stent thrombosis, vascular complications, and/or bleeding events.
This product should not be used in patients who are not likely to comply with the recommended antiplatelet therapy.
PRECAUTIONS
Ensure that the inner package sterile barrier has not been opened or damaged prior to use.
Stent implantation should only be performed by physicians who have received appropriate training.
Stent placement should be performed at hospitals where emergency coronary artery bypass graft surgery (CABG) is accessible.
Subsequent restenosis may require repeat dilatation of the arterial segment containing the stent. Long-term outcomes following repeat dilatation of the stent are presently unknown.
Care should be taken to control the guiding catheter tip during stent delivery, deployment and balloon withdrawal. Before withdrawing the stent delivery system, visually confirm complete balloon deflation by fluoroscopy to avoid guiding catheter movement into the vessel and subsequent arterial damage.
When DES are used outside the specified Indications for Use, patient outcomes may differ from the results observed in the SPIRIT family of trials.
Compared to use within the specified Indications for Use, the use of DES in patients and lesions outside of the labeled indications may have an increased risk of adverse events, including stent thrombosis, stent embolization, MI, or death.
Orally administered everolimus combined with cyclosporine is associated with increased serum cholesterol and triglycerides levels.
A patient’s exposure to drug and polymer is proportional to the number and total length of implanted stents. See Instructions for Use for current data on multiple stent implantation.
Safety and effectiveness of the XIENCE Family of stents have not been established for subject populations with the following clinical settings:
Patients with prior brachytherapy of the target lesion or the use of brachytherapy for treated site restenosis, patients in whom mechanical atherectomy devices or laser angioplasty catheters are used in conjunction with XIENCE Family stents, women who are pregnant or lactating, men intending to father children, pediatric patients, unresolved vessel thrombus at the lesion site, coronary artery reference vessel diameters < 2.25 mm or > 4.25 mm or lesion length > 32 mm, lesions located in saphenous vein grafts, unprotected left main coronary artery, ostial lesions, lesions located at a bifurcation or previously stented lesions, diffuse disease or poor flow (TIMI < 1) distal to the identified lesions, excessive tortuosity proximal to or within the lesion, recent Acute Myocardial Infarction (AMI) or evidence of thrombus in target vessel, multivessel disease, and in-stent restenosis.
Everolimus has been shown to reduce the clearance of some prescription medications when administered orally along with cyclosporine (CsA). Formal drug interaction studies have not been performed with the XIENCE Family of stents because of limited systemic exposure to everolimus eluted from the stent.
Everolimus is an immunosuppressive agent. Consideration should be given to patients taking other immunosuppressive agents or who are at risk for immune suppression.
Oral everolimus use in renal transplant patients and advanced renal cell carcinoma patients was associated with increased serum cholesterol and triglycerides, which in some cases required treatment.
Non-clinical testing has demonstrated that the XIENCE Sierra stent, in single and in overlapped configurations up to 71 mm in length, is MR Conditional. It can be scanned safely under the conditions in the Instructions for Use.
The XIENCE Family of stents should be handled, placed, implanted, and removed according to the Instructions for Use.
POTENTIAL ADVERSE EVENTS
Adverse events (in alphabetical order) which may be associated with percutaneous coronary intervention treatment procedures and the use of a coronary stent in native coronary arteries include, but are not limited to, the following:
Abrupt closure, hematoma, or hemorrhage, Acute myocardial infarction, Allergic reaction or hypersensitivity to latex, contrast agent, anesthesia, device materials (platinum, polymer, cobalt, chromium, nickel, tungsten, acrylic, fluoropolymers), and drug reactions to everolimus, anticoagulation, or antiplatelet drugs, Arterial rupture, Arteriovenous fistula, Arrhythmias, atrial and ventricular, Bleeding complications, which may require transfusion, Cardiac tamponade, Coronary artery spasm, Coronary or stent embolism, Coronary or stent thrombosis, Death, Dissection of the coronary artery, Fever, Hypotension and/or hypertension, Ischemia (myocardial), Myocardial infarction (MI), Nausea and vomiting, Palpitations, Peripheral ischemia, Pseudoaneurysm, Renal Failure, Restenosis, Shock/pulmonary edema, Stroke/cerebrovascular accident (CVA), Total occlusion of coronary artery, Unstable or stable angina pectoris, Vascular access complications which may require vessel repair, Vessel dissection
The risks described below include, but are not limited to, the anticipated adverse events relevant for the cardiac population referenced in the contraindications, warnings, and precautions sections of the everolimus labels.
Live vaccines should be avoided and close contact with those that have had live vaccines should be avoided. Fetal harm can occur when administered to a pregnant woman. There may be other potential adverse events that are unforeseen at this time.
Please Enter the Pop Up text to be displayed in Pop Up here.
AP2946524-WBU Rev. A
DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?
CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.
Precautions
Please be sure to read it.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.
Are you a healthcare professional?
Test
yes
Precautions
Please be sure to read it.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.
Are you a healthcare professional?
Test
[prod, crx3, samplecontent, publish, crx3tar]
test
DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?
CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.
Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.
Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.