Technical Parameters | Unit | Supera™ Peripheral Stent System |
---|---|---|
Construction System | - | Over the Wire (OTW) |
Guide Wire Compatibility | inch | 0.014", 0.018" |
Stent Lengths (vary by stent diameter) | mm | 20, 30, 40, 60, 80, 100, 120, 150 |
Stent Diameters (OD, Outer Diameter)* | mm | 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5 |
Shaft Lengths | cm | 80, 120 |
Sheath Compatibility | F | 6 |
Length (mm) | Stent Diameter (mm) | ||||||
6F, 120 mm | |||||||
4.5 | 5.0 | 5.5 | 6.0 | 6.5 | 7.0 | 7.5 | |
20 | S-45-020-120-P6 | S-50-020-120-P6 | S-55-020-120-P6 | S-60-020-120-P6 | S-65-020-120-P6 | S-70-020-120-P6 | S-75-020-120-P6 |
30 | S-45-030-120-P6 | S-50-030-120-P6 | S-55-030-120-P6 | S-60-030-120-P6 | S-65-030-120-P6 | S-70-030-120-P6 | S-75-030-120-P6 |
40 | S-45-040-120-P6 | S-50-040-120-P6 | S-55-040-120-P6 | S-60-040-120-P6 | S-65-040-120-P6 | S-70-040-120-P6 | S-75-040-120-P6 |
60 | S-45-060-120-P6 | S-50-060-120-P6 | S-55-060-120-P6 | S-60-060-120-P6 | S-65-060-120-P6 | S-70-060-120-P6 | S-75-060-120-P6 |
80 | S-45-080-120-P6 | S-50-080-120-P6 | S-55-080-120-P6 | S-60-080-120-P6 | S-65-080-120-P6 | S-70-080-120-P6 | S-75-080-120-P6 |
100 | S-45-100-120-P6 | S-50-100-120-P6 | S-55-100-120-P6 | S-60-100-120-P6 | S-65-100-120-P6 | S-70-100-120-P6 | S-75-100-120-P6 |
120 | S-45-120-120-P6 | S-50-120-120-P6 | S-55-120-120-P6 | S-60-120-120-P6 | S-65-120-120-P6 | - | - |
150 | - | - | S-55-150-120-P6 | S-60-150-120-P6 | S-65-150-120-P6 | - | - |
Our online product catalogs provide the very latest information available. Download catalogs by product family in PDF format, or view the entire Abbott cardiovascular inventory in Excel. Product barcodes enable direct scanning for easy reordering.
Data on File at Abbott.
MAT-2109827 v1.0
Indications
The Supera™ Peripheral Stent System is indicated to improve luminal diameter in the treatment of patients with symptomatic de novo or restenotic native lesions or occlusions of the superficial femoral artery (SFA) and / or proximal popliteal artery with reference vessel diameters of 4.0 to 7.5 mm, and lesion lengths up to 140 mm.
Contraindications
The Supera™ Peripheral Stent System is contraindicated in:
Warnings
Precautions
The Supera™ Peripheral Stent System should only be used by physicians and medical personnel trained in vascular interventional techniques and trained on the use of this device.
Magnetic Resonance Imaging (MRI) Safety Information
Nonclinical testing has demonstrated that the Supera™ stent, in single and in overlapped configurations up to 250 mm in length, is MR Conditional. A patient with this device can be safely scanned in an MR system meeting the following conditions:
Under the scan conditions defined above, the Supera™ stent is expected to produce a maximum temperature rise of 7.6 °C after 15 minutes of continuous scanning.
In nonclinical testing, the image artifact caused by the device extends approximately 2 cm from the Supera™ stent when imaged with a gradient echo or spin echo sequence and a 3T MRI system.
Potential Adverse Events
Potential adverse events include, but are not limited to: