1
CARDIOVASCULAR
hamburger

Important Safety information

RxSupera™ Peripheral Stent System

Indications

The Supera™ Peripheral Stent System is indicated to improve luminal diameter in the treatment of patients with symptomatic de novo or restenotic native lesions or occlusions of the superficial femoral artery (SFA) and/or proximal popliteal artery with reference vessel diameters of 4.0 to 6.5 mm, and lesion lengths up to 140 mm.

Contraindications

The Supera™ Peripheral Stent System is contraindicated in:

  • patients who are judged to have a lesion that prevents complete inflation of an angioplasty balloon or proper placement of the stent or stent delivery system
  • patients who cannot receive antiplatelet or anticoagulation therapy. Based on in vivo thrombogenicity testing, the device should not be used in patients who cannot be anticoagulated as there may be some thrombus formation in the absence of anticoagulation.

Warnings

  • This device is intended for single-use only. Do not reuse. Do not resterilize. Do not use if the package is opened or damaged.
  • Use this device prior to the “Use By” date as specified on the device package label. Store in a dry, dark, cool place.
  • DO NOT use if it is suspected that the sterility of the device has been compromised.
  • Persons with known hypersensitivities to Nitinol and / or its components (e.g. nickel titanium) may suffer an allergic reaction to this implant.
  • Administer appropriate antiplatelet therapy pre- and post-procedure.
  • Careful attention should be paid when sizing and deploying the stent to prevent stent elongation. In the SUPERB clinical study, stent elongation was associated with a decrease in patency at 12 months.

Precautions

The Supera™ Peripheral Stent System should only be used by physicians and medical personnel trained in vascular interventional techniques and trained on the use of this device.

  • The long-term safety and effectiveness of the Supera™ Peripheral Stent System has not been established beyond three years.
  • The safety and effectiveness of the Supera™ Peripheral Stent System has not been established in patients who:
    • are less than 18 years old
    • are pregnant or lactating
    • have in-stent restenosis of the target lesion
    • have known hypersensitivity to any component of the stent system (e.g., nickel)
    • cannot tolerate contrast media and cannot be pre-treated
    • have uncontrolled hypercoaguability and / or other coagulopathy
  • This device is not designed for use with contrast media injection systems or power injection systems.
  • The flexible design of the Supera™ Stent may result in variation in the deployed stent length.

Magnetic Resonance Imaging (MRI)

A patient with this device can be scanned safely only under specific conditions. Failure to follow the conditions may result in severe injury.

Non-clinical testing has demonstrated the Supera™ Stents are MR Conditional for lengths up to 250 mm. A patient with this stent can be scanned safely, immediately after placement, under the following conditions:

  • Static magnetic field of 1.5 or 3.0 Tesla
  • Highest spatial gradient magnetic field of 2,500 Gauss/cm or less
  • Maximum MR whole-body-averaged specific absorption rate (SAR) of
    • 2 W/kg for landmarks (i.e. center of RF coil) above the umbilicus
    • 1 W/kg for landmarks below the umbilicus and above the mid-thigh
    • 0.5 W/kg for landmarks below the mid-thigh for 15 minutes of scanning (per pulse sequence), operating in the Normal Operating Mode (i.e., MR system mode of operation where there is no physiological stress to the patient). The legs of the patient should not be touching during the procedure.

Potential Adverse Events

Potential adverse events include, but are not limited to:

  • Abrupt closure
  • Allergic reaction (contrast medium; drug; stent material)
  • Amputation or limb loss
  • Aneurysm or pseudoaneurysm in vessel or at vascular access site
  • Angina or coronary ischemia
  • Arrhythmia (including premature beats, bradycardia, atrial or ventricular tachycardia, atrial or ventricular fibrillation)
  • Arteriovenous fistula
  • Bleeding complications requiring transfusion or surgical intervention
  • Death
  • Detachment of a system component or implantation in an unintended site
  • Embolization, arterial or other (e.g. air, tissue, plaque, thrombotic material, or stent)
  • Emergent surgery
  • Fever
  • Hematoma or hemorrhagic event, with or without surgical repair
  • Hyperperfusion syndrome
  • Hypertension / Hypotension
  • Infection
  • Myocardial infarction
  • Pain (leg, foot, and/or insertion site)
  • Partial stent deployment
  • Peripheral nerve injury
  • Pulmonary embolism
  • Renal failure or insufficiency
  • Restenosis of vessel in stented segment
  • Shock
  • Stent malapposition or migration, which may require emergency surgery to remove stent
  • Stent strut fracture
  • Thrombosis or occlusion
  • Stroke
  • Transient ischemic attack
  • Venous thromboembolism
  • Vessel dissection, perforation or rupture
  • Vessel spasm or recoil
  • Worsening claudication or rest pain

CAUTION: This product is intended for use by or under the direction of a physician. Prior to use, reference the Instructions for Use, inside the product carton (when available) or at eifu.abbottvascular.com or at medical.abbott/manuals for more detailed information on Indications, Contraindications, Warnings, Precautions and Adverse Events.

MAT-2008210 v1.0

DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?

CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.

False
accessibility
© 2019 Abbott. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.

accessibility

DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?

CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.