The Advisor™ VL Mapping Catheter, Sensor Enabled™
Bi-Directional. Variable.
Experience the Advisor™ VL Mapping Catheter, Sensor Enabled™, which adds 20 poles and a variable loop on a trusted handling platform. Designed for easy use in simple and straightforward mapping cases, the Advisor VL Mapping Catheter, SE pairs exclusively with the EnSite™ X EP System for diagnostic insight through intelligent automation1, flexibility1* and precision2.

Bi-Directional
Improve versatility and reduce the need for excessive torquing with bi-directional asymmetric shaft deflection7
Variable
Achieve smaller closed diameters compared to Lasso‡ Catheter7
The Advisor™ FL Mapping Catheter, Sensor Enabled™
Exceptional Performance, Enhanced Precision.3
Integrate with the EnSite™ X EP System for precise model creation to facilitate complex arrhythmia diagnoses.5,6 The Advisor™ FL Mapping Catheter, Sensor Enabled™ promotes workflow flexibility, with a design that is built on a cutting-edge shaft and handle platform for excellent performance throughout your entire case.3,4

Precise Model Creation5
Enable precise navigation and model creation with impedance-field flexibility and magnetic-field stability5,6
Create CT-like models4,8 through dense point collection and sensor-based accuracy with the EnSite™ X EP System.
Advanced Handling and Maneuverability
- Navigate to desired cardiac anatomy with 180-degree deflection.
- Available in uni-directional or bi-directional, asymmetric curve options.
- Visualize the catheter position with two electrodes on the shaft.
- Achieve optimal signal quality4,7 from contact with the endocardium using the catheter’s pliable 4 F loop.
References
*The open-platform feature of the EnSite Precision™ cardiac mapping system allows for use of almost any catheter, thus offering superior flexibility as compared to the CARTO‡ system by Biosense Webster‡, which limits use to Biosense Webster catheters only.
- Ptaszek LM, Moon B, Rozen G, Mahapatra S, Mansour M. (2018). Novel automated point collection software facilitates rapid, high-density electroanatomic mapping with multiple catheter types. J Cardiovasc Electrophysiol, 29(1), 186-195. https://doi.org/10.1111/jce.13368.
- Abbott. Data on File. Report 90237452.
- Abbott. Data on File. Report 90214875.
- Abbott. Data on File. Report 90214738.
- Abbott. Data on File. Report 90212729.
- Abbott. Data on File. Report 90215060.
- Abbott. Report on file. 90471601.
- Heist E, Perna F, Chalhoub F, et al. Comparison of Electroanatomical Mapping Systems: Accuracy in Left Atrial Mapping. Pacing Clin Electrophysiol. 2013 May;36(5):626-31. doi: 10.1111/pace.12095. Epub 2013 Feb 25.
MAT-2413535 v1.0
Stay Connected