Product | Model / Reorder Number |
---|---|
PressureWire™ X Guidewire, 175 cm | C12059 |
PressureWire™ X Cabled Guidewire, 175 cm | C12009 |
PressureWire™ X Guidewire, 300 cm | C12359 |
PressureWire™ Receiver | C17040 |
Compatibility with hemodynamic systems: Contact your Abbott Sales Representative
Technical Specifications (Specifications for the combination of PressureWire™ X Guidewire and PressureWire™ Receiver)¹ |
|
---|---|
Pressure range | -30 to +300 mmHg |
Pressure accuracy | ≤2 mmHg or ±2% |
Battery time transmitter | 3 hours |
Frequency range | 2.4000-2.4835 GHz (ISM band) |
Radio type | Frequency-hopping spread spectrum (FHSS) |
Radio power | 1 mW peak, 70 μW average |
Total signal time delay | < 28 ms |
MAT-2011811 v1.0
Indications: The PressureWire™ X Guidewire is indicated to direct a catheter through a blood vessel and to measure physiological parameters in the heart and in the coronary and peripheral blood vessels. Physiological parameters include blood pressure. The PressureWire™ X Guidewire can also measure blood temperature.
Contraindications: This guidewire is contraindicated for use in the cerebral vasculature.
Warnings:
Precautions:
Potential Adverse Events: Potential complications which may be encountered during all catheterization procedures include, but are not limited to: vessel dissection or occlusion, perforation, embolus, spasm, local and/or systemic infection, pneumothorax, congestive heart failure, myocardial infarction, hypotension, chest pain, renal insufficiency, serious arrhythmias, or death.
MAT-2103599 v1.0
Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.
Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.
Precautions
Please be sure to read it.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.
Are you a healthcare professional?
Test