PressureWire X Guidewire

Ordering The PressureWire™ X Guidewire

Product Model / Reorder Number
PressureWire™ X Guidewire, 175 cm C12059
PressureWire™ X Cabled Guidewire, 175 cm C12009
PressureWire™ X Guidewire, 300 cm C12359
PressureWire™ Receiver C17040

Compatibility with hemodynamic systems: Contact your Abbott Sales Representative

Technical Specifications
(Specifications for the combination of
PressureWire™ X Guidewire and PressureWire™ Receiver)¹
Pressure range -30 to +300 mmHg
Pressure accuracy ≤2 mmHg or ±2%
Battery time transmitter 3 hours
Frequency range 2.4000-2.4835 GHz (ISM band)
Radio type Frequency-hopping spread spectrum (FHSS)
Radio power 1 mW peak, 70 μW average
Total signal time delay < 28 ms
Important Safety Information

Reference

  1. PressureWire™ X Guidewire IFU.

MAT-2011811 v1.0

IMPORTANT SAFETY INFORMATION
 

rx-only-logo  PressureWire™ X Guidewire

 

Indications: The PressureWire™ X Guidewire is indicated to direct a catheter through a blood vessel and to measure physiological parameters in the heart and in the coronary and peripheral blood vessels. Physiological parameters include blood pressure. The PressureWire™ X Guidewire can also measure blood temperature.

Contraindications: This guidewire is contraindicated for use in the cerebral vasculature.

Warnings:

  • No modification of this device is allowed.
  • The PressureWire™ X Guidewire is supplied sterile. Discard the guidewire if the pouch is opened or damaged, compromising the sterile barrier. The guidewire is designed for single use only and shall not be reused or resterilized. Adverse effects of using a non-sterile or resterilized guidewire may include, but are not limited to:
    • Local and/or systemic infection
    • Mechanical damage
    • Inaccurate readings
  • Observe all guidewire movements. Whenever the guidewire is moved or torqued, the tip movement should be examined under fluoroscopy. Never push, withdraw, or torque the guidewire if it meets resistance or without observing corresponding movement of the tip, otherwise vessel/ventricle trauma may occur.
  • Torquing or excessive manipulation of the guidewire in a sharp bend, against resistance, or repeated attempts to cross a total vessel occlusion may:
    • Cause dissection or perforation of blood vessels
    • Cause vessel spasm
    • Damage and/or fracture the guidewire
  • When introducing the guidewire, flush the catheter and administer anticoagulation as for a standard catheterization procedure or clotting may occur.
  • Do not use the guidewire in the ventricles if the patient has a prosthetic mechanical or biological valve. It may result in damage to both the prosthesis and the guidewire, which may cause injury or death.
  • Use of the PressureWire™ X Guidewire in conjunction with interventional devices with a short rapid exchange may result in a folded or fractured guidewire.
  • High frequency surgical devices must not be used on a patient at the same time as the guidewire.


Precautions:

  • The PressureWire™ X Guidewire is a delicate instrument and should be handled carefully.
  • Make sure that the transmitter is kept dry to ensure accurate pressure and/or temperature readings. Inaccurate readings may necessitate device replacement.
  • Do not use the guidewire in conjunction with atherectomy catheters. It may damage the guidewire.
  • Do not withdraw or manipulate the guidewire in a sharp-edged object. It may result in abrasion of the guidewire coating.
  • Factors that may affect the accuracy of the diagnostic information include, but are not limited to:
    • Improper placement of the aortic pressure sensor.
    • Failure to achieve maximum coronary and myocardial hyperemia in FFR procedures..
    • Blood flow affected by the position of interventional devices, such as balloon catheters.
  • Guidewire readings may be affected by defibrillation. Rezero the guidewire after defibrillation use.
  • Do not measure pressure when the guidewire sensor element is in a sharp bend or in contact with atrial or ventricular walls. It might result in pressure artifacts.
  • Do not use the PressureWire™ X Guidewire together with another guidewire, for so called jailed wire technique, due to difficulty in guidewire withdrawal and possible guidewire entrapment.
  • Store at room temperature in a dry and dark place.


Potential Adverse Events: Potential complications which may be encountered during all catheterization procedures include, but are not limited to: vessel dissection or occlusion, perforation, embolus, spasm, local and/or systemic infection, pneumothorax, congestive heart failure, myocardial infarction, hypotension, chest pain, renal insufficiency, serious arrhythmias, or death.

MAT-2103599 v1.0

DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?

CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.

False
accessibility
© 2021 Abbott. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.

accessibility

DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?

CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.