TactiFlex™ Duo Ablation Catheter, Sensor Enabled™

Tactiflex Duo System

Indications, Safety & Warnings

Rx Only. Brief Summary: Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events, and directions for use.

United States: Required Safety Information

Indication: TactiFlex™ Duo Ablation Catheter, Sensor Enabled™ is indicated for use in cardiac electrophysiological mapping and ablation for the treatment of drug-refractory recurrent symptomatic paroxysmal atrial fibrillation and concomitant atrial flutter, when used in conjunction with a compatible radiofrequency (RF) or pulsed field (PF) generator and three-dimensional mapping system.  Contraindications: Do not use in patients with active systemic infection, intracardiac thrombus or myxoma, prosthetic heart valves, recent ventriculotomy or atriotomy (<4 weeks), inability to receive adequate anticoagulation, or in patients for whom the specified transseptal or retrograde approaches are contraindicated. Use in the coronary vasculature is contraindicated. Warnings: Application of RF energy on the left atrial posterior wall exceeding 40 W in power, or use of contact force ≥15 g, increases the risk of esophageal perforating complications including atrio-esophageal fistula and death. Application of RF energy outside of the power and duration recommendations may increase the likelihood of steam pop occurrence. The combination of intracoronary placement of the ablation catheter and RF energy application has been associated with myocardial infarction and death. Contact force accuracy above 50 g has not been established. Increased contact force may increase the risk for perforation during manipulation of the catheter. Cases of delayed onset of atrio‑esophageal fistula (AEF) have been reported in association with radiofrequency catheter ablation procedures. While rare, AEF is associated with significant morbidity and mortality. A high index of suspicion for AEF should be maintained in patients who present with symptoms including but not limited to fever, neurological deficits, hematemesis, septic shock, and dysphagia in the several weeks after a left atrial ablation procedure. Inspect tubing, connections, and saline irrigation for air bubbles prior to and throughout its use in the procedure. Air or bubbles in the saline irrigation may cause emboli, potential injury, or fatality. To avoid thromboemboli, intravenous heparin should be used when entering the left heart during ablation. Patients undergoing septal accessory pathway ablation are at risk for complete AV block which requires the implantation of a permanent pacemaker. Permanent pacing may be required in patients who experience inadvertent complete AV block as a result of RF ablation. Implantable pacemakers and implantable cardioverter/defibrillator (ICDs) may be adversely affected by RF or PFA current. It is important to: have temporary external sources of pacing and defibrillation available during ablation, temporarily reprogram the pacing system to minimum output to minimize risk of inappropriate pacing, exercise extreme caution during ablation when in close proximity to atrial or ventricular permanent leads, program the ICD to the OFF mode during the ablation procedure, perform complete implantable device analysis on all patients after ablation. Take precautions to avoid injuring the phrenic nerve, including pacing to identify the proximity of the nerve, and, when using RF, appropriately reducing power. Caution should be taken when placing lesions in the proximity of the specialized conduction system. Collateral anatomical structures need to be considered (e.g. phrenic nerve, coronary arteries and native conduction system) while manipulating catheters and prior to ablation. PF energy should not be applied to the cavotricuspid isthmus. Ablations in areas adjacent to the coronary arteries may lead to coronary artery spasm and/or injury, and the resulting myocardial injury may be fatal. Precautions: Use the catheter only in a fully equipped electrophysiology laboratory. It is recommended that the laboratory should include corresponding equipment including, but not limited to, fluoroscopy, stimulator, recording, defibrillator or ultrasound/intracardiac echocardiography (ICE) units. The PFA therapy should be delivered in accordance with Therapy Delivery Parameters. The first application of PFA will likely result in a significant reduction of  amplitude of PV potentials recorded from the electrodes on the catheter. Do not use this as an immediate indication that no further ablation is necessary. During treatment with the catheter, ensure there is no possibility of contact with the electrodes or guidewire from another catheter. Always straighten the catheter tip before insertion or withdrawal. If irrigation flow is interrupted, immediately inspect and re flush the catheter outside of the patient. Re-establish irrigation flow prior to placing catheter in the body. Irrigated ablation systems have been shown to create larger lesions than standard radiofrequency ablation catheters. Be careful when ablating near electrically vulnerable, thin walled, or other arterial structures. Potential Adverse Events: Potential adverse events include, but are not limited to, death, stroke, transient ischemic attack (TIA), atrio-esophageal fistula (AEF)/esophageal injury, phrenic nerve injury/diaphragmatic paralysis, and serious cardiovascular complications including cardiac tamponade, cardiac perforation, myocardial infarction, heart block requiring permanent pacemaker implantation, pulmonary vein stenosis, thromboembolism, and major bleeding or vascular access complications. Refer to the Instructions for Use for a complete list of adverse events.

MAT-2682754 v1.0