AVEIR VR Leadless Pacemaker

Aveir VR Leadless Pacemaker

Keeping hearts beating  more regularly with the most advanced technologies

 

Using the power of leadless technology, the AVEIR™ VR Leadless Pacemaker is implanted in the heart through a minimally invasive catheter procedure. 

See how the AVEIR VR Leadless Pacemaker works in a patient's heart

Young, vibrant, active – and living her best life with Abbott’s AVEIR VR Leadless Pacemaker. Chelsey needed a pacemaker, and the design of the AVEIR VR leadless pacemaker was the ideal solution for her active lifestyle.

With no wires and no arm restrictions, AVEIR VR leadless pacemaker got her back to the gym and back to life - it’s her safety net. “It catches me when I need it.”


How the AVEIR VR Leadless Pacemaker is implanted1

Aveir Connect

CONNECT patient's skin electrodes to Merlin ProgrammerTM via AVEIRTM Link Module

Aveir Insert

INSERT AVEIR VR Leadless Pacemaker via ergonomic catheter for minimally invasive procedure, ensuring helix is fully covered during catheter navigation

Aveir Map

MAP ventricular implanting location before fixation by touching endocardium with AVEIR VR Leadless Pacemaker's tip electrode

Aveir Fixate

FIXATE the AVEIR VR Leadless Pacemaker to the ventricular endocardium using the screw-in mechanism

Aveir Fixate

RELEASE AVEIR VR Leadless Pacemaker and withdraw delivery catheter

 

For a more detailed workflow, refer to the AVEIR VR Leadless Pacemaker Instructions for Use (IFU) or contact your Abbott Sales Representative for training.



AVEIR VR Leadless Pacemaker Implantation Process Video

Watch an animated depiction of the AVEIR VR Leadless Pacemaker implantation process to see how AVEIR VR Leadless Pacemaker's mapping prior to fixation capabilities and screw-in mechanism create an easy-to-implant workflow and allow for long-term retrieval when the device needs to be replaced.

Download the Physician Brochure to see all AVEIR VR Leadless Pacemaker has to offer

Our Innovative Catheter Technology 

AVEIR Delivery and Retrieval Catheters1,2

  • Designed for ergonomic, single operator use 

  • Steerable delivery catheter with deflection mechanism

  • Hydrophilic coating on introducer sheath and a choice of 30cm and 50cm lengths3

  • Protective sleeve fully covers the AVEIR VR Leadless Pacemaker's helix during catheter navigation in order to reduce the risk of damaging the helix or an injury to cardiovascular structures
catheter

Tri-loop snare re-docking mechanism

catheter

Retrieval Catheter Enables Long-Term Retrieval 

  • AVEIR tri-loop snare re-docking mechanism enables retrieval of the leadless pacemaker

  • AVEIR VR Leadless Pacemaker's active fixation helix uses a screw-in mechanism to enable both implantation and long-term retrieval of the leadless pacemaker1,4

  • The AVEIR VR Leadless Pacemaker's predicate device has a long-term retrieval success rate above 88% with helix fixation through 9 years, regardless of implant duration.4 AVEIR VR Leadless Pacemaker and retrieval catheter are designed for long-term retrieval. Limited data is available for AVEIR VR Leadless Pacemaker 

See the innovations behind AVEIR VR Leadless Pacemaker 

References

 

  1. AVEIR™ VR Leadless Pacemaker and Delivery Catheter IFU. ARTEN600175957
  2. AVEIR™ Retrieval Catheter IFU. ARTMT600167676
  3. AVEIR™ Introducer IFU. ARTMT600167677
  4. Reddy, VY, et al. Worldwide Experience with Leadless Pacemaker Retrievals at 9 years. Presented at 15th Asia Pacific Heart Rhythm Society (APHRS) Scientific Session; Nov 18-20, 2022; Singapore.

MAT-2310326 v2.0 | Item approved for global use. Product not approved in all geographies.