Multiple electrode electrophysiological mapping of cardiac structures in the heart
The Advisor™ HD Grid Mapping Catheter, Sensor Enabled™, is a first-of-its-kind, grid-patterned electrode configuration that offers high-density wave bipole recordings along and across the splines for direction independent mapping.1
Advisor HD Grid Mapping Catheter, SE gives you fast,2 accurate,3 easy-to-use4 high-density cardiac maps.
Features of the Advisor HD Grid Mapping Catheter, Sensor Enabled
Fast mapping time2 and point collection when used in conjunction with the EnSite Precision™ Cardiac Mapping System AutoMap Module and TurboMap features
Placement of 16 electrodes where you need them for faster data collection in a given location2
Accurate3 voltage recordings in direction independent mapping1
Grid pliability and catheter contact to maneuver within any chamber of the heart5
Ability to accurately3 and repeatably6,7 investigate areas of interest to capture information often missed by traditional 10-pole mapping catheters
Address directional sensitivity or bipolar blindness of recordings1
An HD Wave Solution™ software map features data where every electrode utilized has two orthogonal bipoles. When used in conjunction with the EnSite Precision™ Software Best Duplicate Algorithm, the Advisor HD Grid Mapping Catheter, SE shows the highest amplitude data.
Figure 1 shows data gathered using the Advisor HD Grid Mapping Catheter, SE with the HD Wave Solution™ software — compared to standard linear collection.
Fig. 1
Close the Gap: Confirm acute pulmonary vein isolation8
Successful treatment of atrial fibrillation (AF) depends on closing the gap between pulmonary vein isolation (PVI) and pulmonary vein reconnection
Create high-density maps by collecting data in multiple directions
Advisor HD Grid Mapping Catheter, Sensor Enabled mapping technology lets you collect more data for insight into activity that may not be visible for standard 10-pole configuration mapping catheters.8
Karim N, Srinivasan N, Garcia J, et al. (2018). Early experience using the Advisor HD Grid catheter to map atrial fibrillation. European Heart Rhythm Association, 20(4), iv33–iv34. https://doi.org/10.1093/europace/euy205.015
Please Enter the Pop Up text to be displayed in Pop Up here.
MAT-2007558 v2.0
DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?
CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.
Precautions
Please be sure to read it.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.
Are you a healthcare professional?
Test
yes
Precautions
Please be sure to read it.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.
Are you a healthcare professional?
Test
[prod, crx3, samplecontent, publish, crx3tar]
test
DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?
CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.
Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.
Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.