Multiple electrode electrophysiological mapping of cardiac structures in the heart
The Advisor™ HD Grid Mapping Catheter, Sensor Enabled™, is a first-of-its-kind, grid-patterned electrode configuration that offers high-density wave bipole recordings along and across the splines for direction independent mapping.1
Advisor HD Grid Mapping Catheter, SE gives you fast,2 accurate,3 easy-to-use4 high-density cardiac maps.
Features of the Advisor HD Grid Mapping Catheter, Sensor Enabled
- Steerable, flexible, insulated electrophysiology catheter
- Fast mapping time2 and point collection when used in conjunction with the EnSite Precision™ Cardiac Mapping System AutoMap Module and TurboMap features
- Placement of 16 electrodes where you need them for faster data collection in a given location2
- Accurate3 voltage recordings in direction independent mapping1
- Grid pliability and catheter contact to maneuver within any chamber of the heart5
- Ability to accurately3 and repeatably6,7 investigate areas of interest to capture information often missed by traditional 10-pole mapping catheters
Address directional sensitivity or bipolar blindness of recordings1
An HD Wave Solution™ software map features data where every electrode utilized has two orthogonal bipoles. When used in conjunction with the EnSite Precision™ Software best duplicate algorithm, the Advisor HD Grid Mapping Catheter, SE shows the highest amplitude data.
Figure 1 shows data gathered using the Advisor HD Grid Mapping Catheter, SE with the HD Wave Solution™ Technology — as well as standard linear collection.

Close the Gap: Confirm acute pulmonary vein isolation8
Successful treatment of atrial fibrillation (AF) depends on closing the gap between pulmonary vein isolation (PVI) and pulmonary vein reconnection
Create high-density maps by collecting data in multiple directions
Advisor HD Grid Mapping Catheter, SE mapping technology lets you collect more data for insight into activity that may not be visible for standard 10-pole configuration mapping catheters.8


This device is commercially available for use in select international markets.
References
- Abbott. Report on file. 90280703.
- Abbott. Report on file. 90299533.
- Abbott. Report on file. 90262900.
- Abbott. Report on file. 90355919.
- Abbott. Data on file. Report 90248530.
- Abbott. Data on file. Report 90264963.
- Abbott. Data on file. Report 90283998.
- Karim N, Srinivasan N, Garcia J, et al. (2018). Early experience using the Advisor HD Grid catheter to map atrial fibrillation. European Heart Rhythm Association, 20(4), iv33–iv34. https://doi.org/10.1093/europace/euy205.015
MAT-2009606 v3.0