About Durata Defibrillation Lead | Abbott
CARDIOVASCULAR
hamburger

About

Designed to Meet Challenges with Durability

The Durata™ defibrillation lead is a cardiac lead designed to offer high-performance handling, more control at implant and a proven platform of long-term durability.

Lead Reliability with Optim Lead Insulation

The Durata defibrillation lead has a proven structural design. It uses Optim™ lead insulation — a unique material with excellent long-term durability1 — and thin, 7 Fr sizing, which better accommodates multiple leads in a single vessel.

The Durata defibrillation lead is designed to deal with challenging ICD lead cases, including cases requiring multi-lead systems, lead replacement or with patients who have small or tortuous veins.

Long-Term Performance

Durata defibrillation lead uses exclusive Optim lead insulation, a unique hybrid of silicone and polyurethane, designed to:

  • Minimize lead abrasion
  • Increase flexibility and lubricity
  • Provide lead-on-lead and lead-on-can abrasion resistance in multi-lead systems
  • Restrict tissue growth into shock coils, by utilizing flat-wire coils with silicone backfill

Research and more than 10 years of data has shown what  defibrillation leads with Optim insulation offer:

98.9%

Freedom

from all-cause insulation abrasion2

95.9%

Freedom

from all-cause mechanical failure2

Confidence at Implant

The 7 Fr Durata lead helps physicians navigate challenging anatomy. It is lubricious and flexible — and it is the smallest ICD lead available today.

The Durata lead was designed to:

  • Improve passage through crowded veins
  • Provide more options for lead access in the smaller cephalic vein
  • Increase maneuverability in patients with small or tortuous veins
  • Accommodate multiple or pre-existing leads in a single vessel

The DF4 Connector Header Difference

The DF4 connector header has a single terminal pin connection, which decreases chances of lead-to-port mismatch. Fewer connections and setscrews lessen complexity, and the improved terminal pin visibility is designed to encourage proper lead connection.

Sign Up for Updates

References

  1. Abbott. Product Performance Report. 2020. 1st edition. SJM-ELP-90624466 REV A.
  2. Cairns, et. al., Low rates of mechanical failures of silicone-polyurethane copolymer-coated ICD leads: 11 years prospective follow-up. ESC. 2019.

MAT-2011139 v1.0

DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?

CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.

False
accessibility
© 2021 Abbott. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.

accessibility

DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?

CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.