Read journal articles, abstracts and other clinical evidence related to CRT management and the Quartet™ Quadripolar LV Lead:
-
Multipoint pacing is associated with reduction of heart failure hospitalizations or death in patients who do not respond to cardiac resynchronization therapy: results of the MORECRT MPP randomized trial.
Leclercq C, Burri H, Calò L, Rinaldi CA, Sperzel J, Thibault B et al. EP Europace, euaf070.
Conclusions: In the MORE-CRT MPP randomized trial, MPP was associated with a significant reduction of all-cause mortality and HF hospitalizations in prior non-responders to conventional biventricular pacing.
-
Multipoint pacing is associated with improved prognosis and cardiac resynchronization therapy response: MORECRT MPP randomized study secondary analyses.
Leonardo Calò, Ermenegildo De Ruvo, Christof Kolb, Amir Janmohamed, Pedro Marques, Pascal Defaye, ...Christophe Leclercq, on behalf of the MORE-CRT MPP Investigators, EP Europace, euae259.
Conclusions: In patients who do not respond to standard CRT despite the high BIV pacing percentage, MPP is associated with lower occurrence of HF hospitalizations and higher probability of reverse LV remodelling compared with BIV pacing.
-
Turakhia, M., Cao, M., Fischer, A., Nabutovsky, Y., Sloman, L. S., Dalal, Nirav., Gold, M. R. (2018). J Am Coll Cardiol EP. 2(4). 426-33.
Conclusions: In this observational study of CRT-D devices, use of a quadripolar, compared to a bipolar LV lead, was associated with a reduction in LV lead deactivation, replacement, and mortality.
-
Corbisiero, R., Kazemian, P., Bharmi, R., Shar, R., Muller, D. (2016). PACE 39(10). 1038-1045.
Conclusion: This U.S. economic comparative study demonstrated that QUAD exhibited lower postimplant inpatient HFH rates and reduced healthcare utilization compared to BIP systems.
-
Forleo, G. B., Di Biase, L., Bharmi, R., Dalal, N., Panattoni, G., Pollastrelli, A., … Romeo, G. (2015). Europace, 17(1), 101-107.
Conclusions: In this comparative effectiveness assessment of well-matched groups of CRT-D patients with quadripolar and bipolar LV leads, QUAD patients experienced a lower rate of hospitalizations for HF and LV lead surgical revision, and a lower cost burden. This has important implications for LV pacing lead choice.
-
Tomassoni, G. Baker, J., Corbisiero, R., Love, C., Martin, D., Niazi, I., … Zhang, Z. (2013). J Cardiovasc Electrophysiol 24(4). 449-456.
Conclusions: The Quartet LV lead electrical performance was stable and was associated with a high implant success and low dislodgement rate during 3‐month follow‐up. In all patients with PNS, the 10 pacing vectors combined with reduced output programming enabled the elimination of PNS noninvasively.
-
Turakhia, M. P., Gold, M. R., Fischer, A., Sloman, L. S., Kumar, C., Dalal, N., … Cao, M., (2013). Europace, 15(Suppl. 2), S47.
Conclusions: Compared to traditional bipolar LV leads, use of the Quartet LV lead was associated with a significantly lower rate of deactivation or replacement at 3 months post-implant. At both initial programming and during follow-up, nearly half of all Quartet LV lead patients were programmed to vectors unique to the Quartet LV lead.
-
Sperzel, J., Dänschel, W., Gutleben, K. J., Kranig, W., Mortensen, P., Connelly, D., … Rinaldi, C. A. (2012). Europace, 14(3), 365-372.
Conclusion: The new quadripolar electrode LV lead provides more programming options to address common problems faced when managing CRT patients. Electrical measurements from new vectors are comparable with conventional configurations. Furthermore, 11% of patients in the study suffered PNS on all conventional bipolar vectors.
-
Forleo, G. B., Mantica, M., Di Biase, L., Panattoni, G., Della Rocca, D. G., Papavasileiou, L. P., … Romeo, F. (2012). Heart Rhythm, 9(11), 1822-1828.
Conclusion: Over the longer term, CRT with the quadripolar LV lead is associated with excellent pacing thresholds, low rates of dislocations, and PNS.
-
Mehta, P. A., Shetty, A. K., Squirrel, M., Bostock, J., & Rinaldi, C. A. (2012). Journal of Interventional Cardiac Electrophysiology, 33(1), 43-49.
Conclusion: The quadripolar Quartet LV lead is associated with a high implant success rate, stable pacing parameters and a low displacement rate during the first 6 months after implant. The ten LV pacing vectors available with this lead allowed PNS and capture threshold problems to be overcome at implant, and importantly at follow-up, thus obviating the need for lead reposition.
-
Forleo, G. B., Della Rocca, D. G., Papavasileiou, L. P., Molfetta, A. D., Santini, L., & Romeo, F. (2011). Heart Rhythm, 8(1), 31-37.
Conclusion: This prospective, controlled study provides strong evidence that CRT with the quadripolar LV lead results in low rates of dislocations and phrenic nerve stimulation.
-
Jenney, C., Tan, J., Karicherla, A., Burke, J., & Helland, J. (2005). Heart Rhythm, 2(5), S318-319.
Conclusions: The new SPC™ insulation exhibits significantly improved performance over both silicone rubber and polyurethane. Its flexibility and softness can result in a substantial reduction of lead tip stiffness compared to polyurethane 55D. Invivo testing has shown that biostability of the SPC™ is at least as good as, or better than current polyurethane 55D. SPC™ is expected to be a reliable insulation for future use in cardiac leads. Further studies with SPC are in progress.