UltiSynq™ Defibrillation Lead
Precise Positioning Solution for Left Bundle Branch Pacing (LBBP) Capture,Φ
Without Compromising ICD Function1,2
Controlled Torque Transmission for Consistent, Confident LBBP Capture1,3
Engineered to address challenging anatomy often encountered in ICD and CRT-D patients.1,3 Continuous monitoring of depth assessment supports successful placement, mitigating multiple adjustments and optimizing procedure time.
Built on a Proven ICD Lead Coil Design+,1
Built with a proven defibrillation lead coil design, the UltiSynq enables left bundle branch capture without compromising shock efficacy.1,2
Defibrillation success without lead repostioning1
Complication free rate at 3 months, exceeding the pre-specified performance goal1
True Bipolar Design Delivers Accurate Sensing1
True bipolar sensing simplifies lead slack management and
device programming.Ω,4
Clinically Proven to Power Conduction System Pacing (CSP)
A high-voltage CSP lead built on proven structural defibrillation lead design, the UltiSynq Defibrillation Lead is designed to provide confidence moving forward into left bundle branch area pacing (LBBAP).
LBBAP implant success rate
Freedom from over-sensing
Discover the Clinical Evidence
Presenting as part of the late-breaking clinical study at Heart Rhythm 2026, Dr. Robert Schaller highlights data establishing how Abbott’s innovative conduction system pacing (CSP) solutions are optimizing left bundle branch area pacing (LBBAP) for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) systems without compromising defibrillation performance.
Powering CSP Innovation with the Confidence of Proven Defibrillation Platforms
Distal flex fatigue testing was configured to challenge the lead survivability at stress levels higher than expected when used clinically in the LBBA. Testing was successfully conducted to 400 million cycles, simulating 10 years of service, with no sample failures.5
Reduced distal fatigue on the lead when placed in the left bundle branch area (LBBA)
- Demonstrated in modeling data and in vivo comparison to the models
- Increased flex durability in the LBBA
Successful Delivery and Implant
The UltiSynq Defibrillation Lead and CPS Locator™ 3D Plus Delivery Catheters enable successful lead delivery to the LBBA in a variety of locations along the septum.
MR Conditional. Allows patients to safely undergo an MRI scan when used in combination with an MRI-Ready device.*
Stay Informed
Sign up to hear about our technology, education opportunities, and more.
Read the Latest Blog Article
Stay up to date with recent news, product highlights, and case studies.
Footnotes:
All clinical data shown are based on results from the ASCEND CSP clinical trial.
Φ 86% of patients achieved LBBP or likely LBBP capture1
+The UltiSynq defibrillation lead coil design is based on commercially available and established defibrillation leads
ΩCompared to additional lead slack management and programming steps observed with integrated bipolar leads4
*For additional information about specific MR Conditional systems and lead model numbers, including warnings, precautions, adverse conditions to MRI scanning and potential adverse events, please refer to the MRI-Ready Systems Manual at manuals.eifu.abbott or check our MRI-Ready resources at medical.abbott/manuals.
References:
- Schaller RD, Sanders P, Joza J, Zimetbaum P, Birgersdotter-Green U, Tung R, Singh B, Tam MTK, Thomaides A, Nair D, Leclercq C, Vijayaraman P, Hadadi CA, Wiley J, Ganz L, Feng L, Johnson G, Ryu K, Shaw R, Charan V, Lee K, Burri H; ASCEND CSP Investigators. Safety and performance of a novel ICD lead for left bundle branch area pacing: Results from the ASCEND CSP trial. Heart Rhythm. 2026 Apr 25:S1547-5271(26)02194-6. doi: 10.1016/j.hrthm.2026.03.1939. Epub ahead of print. PMID: 42033435.
- J. Requena-Carrion, J. Vaisanen, F. Alonso-Atienza, J. L. Rojo-Alvarez, J. Hyttinen and A. Garcia-Alberola, "Comparison of the scope of true and integrated bipolar leads in implantable cardioverter defibrillators," 2007 Computers in Cardiology, Durham, NC, USA, 2007, pp. 233-236, doi: 10.1109/CIC.2007.4745464.
- Data on File (Torque Transmission Assessment for UltiSynq and UltiPace Leads (91190757 Rev A))
- Medtronic Left bundle brancharea pacing (LBBAP) Implant procedure reference guide (US-CV-2600638 v1.0)
- Summary Report for Distal End Analysis and Testing of UltiSynq Leads Used in the Left Bundle Branch Area. Data on file. Report 91171473 Rev. A.
Rx Only
Brief Summary: Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.
UltiSynq™ Defibrillation Leads
Indications for Use: The UltiSynq™ defibrillation lead is indicated for use in combination with implantable cardioverter defibrillators (ICD) and cardiac resynchronization therapy‑defibrillators (CRT‑D) to provide sensing, pacing, and cardioversion/defibrillation therapy in patients who are at risk of sudden cardiac death due to bradyarrhythmias or life‑threatening tachyarrhythmias. The lead may be implanted transvenously in either the left bundle branch area or the right ventricle.
Intended Use: The UltiSynq™ defibrillation lead is intended for use with a compatible pulse generator to provide long‑term cardiac pacing and sensing in the right ventricle or the left bundle branch area, cardioversion/defibrillation therapy to treat life‑threatening ventricular arrhythmias, and biventricular pacing when used with a coronary sinus lead.
Contraindications: UltiSynq™ defibrillation lead, is contraindicated:
- in the presence of tricuspid atresia and significant tricuspid stenosis
- for patients with mechanical tricuspid valves
- for patients with a history of ventricular septal defect, repair, or both
- in patients who are expected to be hypersensitive to device material components or a single dose of 1.0 milligram of dexamethasone sodium phosphates
- in the presence of any condition that precludes adequate vascular access
- for patients with active systemic infection
For contraindications of the ICD/CRT‑D device used with the UltiSynq defibrillation lead, please refer to the applicable pulse generator manual.
Adverse Events: Potential adverse events and their categories as applicable when using an UltiSynq™ defibrillation lead include: Arrhythmia (Accelerated arrhythmia, Induced atrial ectopy or arrhythmias, Induced ventricular ectopy or asystole, Myocardial irritability), Damage to the Conduction System (Complete heart block, Right bundle branch block), Coronary sinus or coronary vein perforation/dissection, coronary artery perforation, Coronary vessel fistula, Cardiac perforation (Cardiac tamponade, Pericardial Effusion, Pericarditis, Septal perforation), Death, Embolism (Air embolus, Thromboembolism, Foreign body), Device related thrombus, Extra-cardiac stimulation, Heart failure (HF decompensation, Cardiogenic shock), Pacing-induced cardiomyopathy, Tricuspid valve dysfunction/insufficiency (Tricuspid regurgitation), Tricuspid valve injury, Hypersensitivity, including local tissue reaction or allergic reaction, Infection (Endocarditis), Lead dislodgement, Hemothorax, Pneumothorax, Pulmonary edema, Respiratory compromise, Septal hematoma, Vascular injury (Vascular perforation, Dissection, Arteriovenous fistula), Hemorrhage/ Hematoma at access site, Vascular thrombosis, Lead revision resulting from, but not limited to, loss of pacing and/ or sensing (Electrical malfunction of the lead, Lead dysfunction with no clear electrical and mechanical cause, Oversensing, Undersensing, Capture threshold elevation, Mechanical malfunction of the lead), Inappropriate defibrillation therapy, Loss of capture, Loss of defibrillation therapy, Prolonged exposure to fluoroscopic radiation, Contrast media, Anesthesia risks.
Refer to the User’s Manual for detailed indications, contraindications, warnings, precautions and potential adverse events.
CPS Locator™ 3D Plus Delivery Catheter
Indications for Use:
he Delivery Catheter is indicated for the introduction of various types of catheters and pacing or defibrillator leads to the right heart, inclusive of the Left Bundle Branch Area.
Contraindications:
• Obstructed or inadequate vasculature for venous access
• Review contraindications associated with ancillary devices used with the Delivery Catheter
Complications: Possible complications associated with the Delivery Catheter include: Delay in procedure, Vessel trauma, Endocardial trauma, Air ingress, Blood loss, Lead Dislodgement, Embolization (material, air), Allergic reaction, Infection, Device incompatibility, Incomplete therapy. Possible complications associated with the use of ancillary devices with the Delivery Catheter include: Air embolism, Bleeding, Bradycardia, Cardiac perforation, Cardiac tamponade, Chronic nerve damage, Death, Extracardiac stimulation (muscle/nerve stimulation), Hematoma, Heart block, Hemothorax, Incisional pain, Infection including endocarditis, Lead dislodgement, Myocardial infarction, Myocardial trauma, Pericardial effusion, Pericarditis, Pneumothorax, Stroke, Tachyarrhythmias, Thrombosis/thromboemboli, Valve damage, Venous occlusion, Venous trauma (e.g., perforation, dissection, erosion).
Refer to the User’s Manual for detailed indications, contraindications, warnings, precautions, and potential adverse events.