Keeping hearts beating more regularly with the most advanced technologies
Using the power of leadless technology, the AVEIR™ VR Leadless Pacemaker is implanted in the heart through a minimally invasive catheter procedure.
See how the AVEIR VR Leadless Pacemaker works in a patient's heart
Young, vibrant, active – and living her best life with Abbott’s AVEIR VR Leadless Pacemaker. Chelsey needed a pacemaker, and the design of the AVEIR VR leadless pacemaker was the ideal solution for her active lifestyle.
With no wires and no arm restrictions, AVEIR VR leadless pacemaker got her back to the gym and back to life - it’s her safety net. “It catches me when I need it.”
How the AVEIR VR Leadless Pacemaker is implanted1

CONNECT patient's skin electrodes to Merlin ProgrammerTM via AVEIRTM Link Module

INSERT AVEIR VR Leadless Pacemaker via ergonomic catheter for minimally invasive procedure, ensuring helix is fully covered during catheter navigation

MAP ventricular implanting location before fixation by touching endocardium with AVEIR VR Leadless Pacemaker's tip electrode

FIXATE the AVEIR VR Leadless Pacemaker to the ventricular endocardium using the screw-in mechanism

RELEASE AVEIR VR Leadless Pacemaker and withdraw delivery catheter
For a more detailed workflow, refer to the AVEIR VR Leadless Pacemaker Instructions for Use (IFU) or contact your Abbott Sales Representative for training.
Download the Physician Brochure to see all AVEIR VR Leadless Pacemaker has to offer


Our Innovative Catheter Technology
AVEIR Delivery and Retrieval Catheters
- Designed for ergonomic, single operator use
- Steerable delivery catheter with deflection mechanism1,2
- Hydrophilic coating on introducer sheath and a choice of 30cm and 50cm lengths3
- Protective sleeve fully covers the AVEIR VR Leadless Pacemaker's helix during catheter navigation in order to reduce the risk of damaging the helix or an injury to cardiovascular structures1,2

Tri-loop snare re-docking mechanism

Retrieval Catheter Enables Chronic Retrieval
- AVEIR tri-loop snare re-docking mechanism enables retrieval of the Leadless Pacemaker
- AVEIR VR Leadless Pacemaker's active fixation helix uses a screw-in mechanism to enable both implantation and chronic retrieval of the Leadless Pacemaker1,4
- The AVEIR VR Leadless Pacemaker's predicate device has a chronic retrieval success rate above 80% with helix fixation through 7 years, regardless of implant duration.4 AVEIR VR Leadless Pacemaker and retrieval catheter are designed for chronic retrieval. Limited data is available for AVEIR VR Leadless Pacemaker
See the innovations behind AVEIR VR Leadless Pacemaker
References
- Aveir™ VR Leadless Pacemaker and Delivery Catheter IFU. ARTEN600175956
- Aveir™ Retrieval Catheter IFU. ARTMT600174816
- Aveir™ Introducer IFU. ARTEN600174817
- Reddy VY, et al. Chronic Retrievability with a Leadless Pacemaker: A Worldwide Nanostim Experience out of 7y. Presented at: HRS 2021; Jul 28-31, 2021; Boston, MA.
MAT-2210337 v1.0 | Item approved for Canada use only.
Disclaimer
You are about to enter an Abbott country- or region-specific website.
Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions
Do you wish to continue and enter this website?
MAT-2305078 v1.0