Over 20 years ago, we pioneered PFO closure with the Amplatzer™ PFO Occluder. Today, it is the most-studied — and most-trusted — device of its kind, with over 180,000 patients treated worldwide.2
And our clinical evidence is unmatched, thanks to the largest-ever trial for PFO closure, boasting 5,810 patient-years of data.3
With the introduction of the Amplatzer™ Talisman™ PFO Occluder, we have built upon the proven Amplatzer PFO closure technology. We've added the 30mm size so you have the complete PFO portfolio for every case. And the occluder now comes assembled and ready to use, simplifying prep and enhancing ease-of-use.
The easy-to-use just got easier.
NEW VERSION AVAILABLE
GET THE AMPLATZER™ PORTFOLIO APP
The Amplatzer™ App helps physicians choose the right Amplatzer™ device to meet the needs of each case.
Simple PFO or PFO with a non-prominent ASA
PFO where a secure device position and effective PFO closure can be achieved when using the 25 mm device size
Absence of ASA, long tunnel, and thickened septum secundum
Non-prominent ASA (<20 mm total excursion) without a long tunnel (≥ 10 mm length) and without a thickened septum secundum (≥ 10 mm thickness)
25
Complex PFO
PFO with one or more anatomical characteristics that may complicate the ability to achieve a secure device position and effective PFO closure when using the 25 mm device size
ASA (≥ 10 mm excursion) with long tunnel (≥ 10 mm length)
ASA (≥ 10 mm excursion) with thickened septum secundum (≥ 10 mm thickness)
Prominent ASA with excessive mobility (≥ 20 mm total excursion)
Lipomatous hypertrophy of septum secundum (≥ 15 mm thickness)
30 or 35
PFO with small anatomy
Anatomy not suitable for 25 mm device size secondary to interference with adjacent cardiac structures
Septal primum length < 20 mm
18
Note: Evaluate the position of the device after deployment, but before detachment. Use echocardiography to ensure that the device does not impinge on the free atrial wall or aortic root. If the device interferes with an adjacent cardiac structure (such as free atrial wall or aortic root), recapture the device and redeploy. If device position remains unsatisfactory, recapture the device and either replace with a smaller device (18 mm or 25 mm) or refer the patient for alternative treatment.
The presence of an ASA alone does not necessarily prevent successful PFO closure with a 25 mm device size. In RESPECT1, 180 patients (36%) in the device closure group had an ASA. The 25 mm device size was used in the majority of patients with an ASA (77%) to close the PFO, and at 6-months post-implant, effective closure was achieved in 95% of these patients. There were no cases of device embolization in any patient in the study
1. Saver JL, Carroll JD, Thaler DE, et al. Long-term outcomes of patent foramen ovale closure or medical therapy after stroke. N Engl J Med. 2017;377:1022-32.
References
Tests performed by and data on file at Abbott.
Abbott data on file.
Saver JL, Carroll JD, Thaler DE, et al. Long-term outcomes of patent foramen ovale closure or medical therapy after stroke. N Engl J Med. 2017; 377: 1022-32.
The Amplatzer™ Talisman™ PFO Occluder is indicated for percutaneous transcatheter closure of a patent foramen ovale (PFO) to reduce the risk of recurrent ischemic stroke in patients, predominantly between the ages of 18 and 60 years, who have had a stroke due to a presumed paradoxical embolism, as determined by a neurologist and cardiologist following an evaluation to exclude other causes of ischemic stroke.
CONTRAINDICATIONS
Presence of thrombus at the intended site of implant, or documented evidence of venous thrombus in the vessels through which access to the defect is gained.
Patients with intra-cardiac thrombus, mass, vegetation, or tumor.
Patients whose vasculature, through which access to the PFO is gained, is inadequate to accommodate the appropriate sheath size.
Patients with anatomy in which the required Amplatzer™ Talisman™ PFO device size would interfere with other intracardiac or intravascular structures, such as valves or pulmonary veins.
Patients with another source of right-to-left shunts, including an atrial septal defect and/or fenestrated septum.
Patients with active endocarditis or other untreated infections.
Patients who are unable to tolerate intra-procedural anticoagulation or post-procedural anti-platelet therapy.
WARNINGS
Do not use an open or damaged pouch; do not use a damaged device.
Patients who are at increased risk for venous thromboembolic events should be managed with thromboembolic risk reduction regimen after the PFO closure following standard of care.
The safety and effectiveness of the Amplatzer™ Talisman™ PFO Occluder has not been established in patients with a hypercoagulable state.
Prepare for situations that require percutaneous or surgical removal of this device. This includes availability of a surgeon and access to operating room.
Embolized devices must be removed as they may disrupt critical cardiac functions. Do not remove an embolized occluder through intracardiac structures unless the occluder is fully recaptured inside a catheter or sheath.
The Amplatzer™ Talisman™ PFO Occluder device consists of a nickel-titanium alloy, which is generally considered safe. However, in vitro testing has demonstrated that nickel is released from this device for a minimum of 60 days. Patients who are allergic to nickel may have an allergic reaction to this device, especially those with a history of metal allergies. Certain allergic reactions can be serious; patients should be instructed to notify their physicians immediately if they suspect they are experiencing an allergic reaction such as difficulty breathing or inflammation of the face or throat. Some patients may also develop an allergy to nickel if this device is implanted.
Transient hemodynamic compromise may be encountered during device placement, which may require fluid replacement or other medications as determined by the physician.
Prior to device detachment, evaluate the position of the device relative to the free atrial wall and the aortic root using echocardiography.
Use echocardiography to ensure that the device does not impinge on the free atrial wall or aortic root.
Do not release the device from the delivery cable if the device does not conform to its original configuration, or if the device position is unstable or if the device interferes with any adjacent cardiac structure (such as Superior Vena Cava (SVC), Pulmonary Vein (PV), Mitral Valve (MV), Coronary Sinus (CS), aorta (AO)). If the device interferes with an adjacent cardiac structure, recapture the device and redeploy. If still unsatisfactory, recapture the device and either replace with a new device or consider alternative treatments.
DO NOT use the Amplatzer™ Talisman™ PFO Occluder after the Use-by date stated on the package label.
This device was sterilized with ethylene oxide and is for single use only. Never reuse or re-sterilize the system. Use of expired, reused, or re-sterilized devices may result in infection.
This device should be used only by physicians who are trained in standard transcatheter techniques.
PRECAUTIONS FOR SPECIAL POPULATIONS
Pregnancy: The safety and effectiveness of this occluder has not been established during pregnancy. Fluoroscopic x-ray guidance is used during placement of the device. The risk of increased X-ray exposure for patients who are pregnant must be weighed against the potential benefits of this technique.
Nursing mother: The safety and effectiveness of this occluder has not been established in lactating mothers. There has been no quantitative assessment for the presence of leachables in breast milk.
Pediatric Population: The safety and effectiveness of this occluder has not been established in a pediatric population.
PRECAUTIONS
Aspirin (325 mg/day) (or alternative antiplatelet/anticoagulant, if patient has aspirin intolerance) is recommended to be started at least 24 hours prior to the procedure.
Antibiotics should be administered peri-procedurally.
Patients should be fully heparinized throughout the procedure using adequate dosing so as to keep the activated clotting time (ACT) greater than 200 seconds.
CAUTION: Intracardiac echocardiography (ICE) or transesophageal echocardiography (TEE) is recommended as an aid in evaluating the PFO and placing the Amplatzer™ Talisman™ PFO Occluder. If TEE is used, the patient’s esophageal anatomy must be adequate for placement.
CAUTION: Be cautious when using fluoroscopic X-ray guidance, which may be used during placement of the device.
CAUTION: Do not use a power injection system to put contrast solution through the sheath.
The safety and effectiveness of the Amplatzer™ Talisman™ PFO Occluder has not been established in patients (with):
Age less than 18 years or greater than 60 years because enrollment in the pivotal study (the RESPECT trial) was limited to patients 18 to 60 years old
A hypercoagulable state including those with a positive test for a anticardiolipin antibody (IgG or IgM), Lupus anticoagulant, beta-2 glycoprotein-1 antibodies, or persistently elevated fasting plasma homocysteine despite medical therapy
Unable to take antiplatelet therapy
Atherosclerosis or other arteriopathy of the intracranial and extracranial vessels associated with a ≥50% luminal stenosis
Acute or recent (within 6 months) myocardial infarction or unstable angina
Left ventricular aneurysm or akinesis
Mitral valve stenosis or severe mitral regurgitation, irrespective of etiology
Aortic valve stenosis (mean gradient greater than 40 mmHg) or severe aortic valve regurgitation
Mitral or aortic valve vegetation or prosthesis
Aortic arch plaques protruding greater than 4 mm into the aortic lumen
Left ventricular dilated cardiomyopathy with left ventricular ejection fraction (LVEF) less than 35%
Chronic, persistent, or paroxysmal atrial fibrillation or atrial flutter
Uncontrolled hypertension or uncontrolled diabetes mellitus
Diagnosis of lacunar infarct probably due to intrinsic small vessel as qualifying stroke event
Arterial dissection as cause of stroke
Index stroke of poor outcome (modified Rankin score greater than 3)
Pregnancy at the time of implant
Multi-organ failure
PATIENT COUNSELING INFORMATION Physicians should review the following information when counseling patients about the Amplatzer™ Talisman™ PFO Occluder and the implant procedure:
The safety and effectiveness of PFO closure with the Amplatzer™ Talisman™ PFO Occluder in combination with the required postimplant antiplatelet therapy.
PFO closure with the Amplatzer™ Talisman™ PFO Occluder can only reduce the risk for a recurrent stroke due to a paradoxical embolism through a PFO.
With aging, there is an increased likelihood that non-PFO related risks for stroke may develop and cause a recurrent ischemic stroke independent of PFO closure.
The procedural risks associated with Amplatzer™ Talisman™ PFO Occluder.
The need for adherence to a defined adjunctive antithrombotic therapy following implantation of the Amplatzer™ Talisman™ PFO Occluder.
Patients with a history of DVT or PE may benefit from continuation or resumption of anticoagulation therapy following implantation of the Amplatzer™ Talisman™ PFO Occluder to reduce the risk of recurrent DVT or PE.
It is recommended that the medical team (neurologist and cardiologist) and the patient engage in a shared decision-making process and discuss the risks and benefits of PFO closure in comparison to using antithrombotic therapy alone, while taking into account the patient’s values and preferences.
POTENTIAL ADVERSE EVENTS Potential adverse events that may occur during or after a procedure using this device may include, but are not limited to:
Air embolus
Allergic reaction/toxic effect due to: anesthesia, contrast media, medication, or metal
Arrhythmia
Arteriovenous fistulae
Bleeding
Cardiac perforation
Cardiac tamponade
Chest pain
Death
Deep vein thrombosis
Device embolization
Device erosion
Endocarditis
Esophagus injury
Fever
Headache/migraine
Hematoma
Hypertension/hypotension
Infection
Myocardial infarction
Pacemaker placement secondary to PFO device closure
Pain
Pericardial effusion
Pericarditis
Peripheral embolism
Pseudoaneurysm
Pulmonary embolism
Reintervention for residual shunt/device removal
Stroke
Transient ischemic attack
Thrombus formation
Valvular regurgitation
Vascular access site injury
Vessel perforation
AMPLATZER™ TALISMAN™ DELIVERY SHEATH
INDICATIONS FOR USE
The Amplatzer™ Talisman™ Delivery Sheath is indicated to provide a pathway through which an Amplatzer™ PFO Occluder is introduced for patent foramen ovale closure.
CONTRAINDICATIONS
None known.
WARNINGS
This device was sterilized with ethylene oxide and is for single use only. Do not reuse or resterilize this device. Attempts to resterilize this device can cause a malfunction, insufficient sterilization, or harm to the patient.
Do not use this device if the sterile package is open or damaged. Inspect all components before use. Do not use if the package or items appear to be damaged or defective.
DO NOT use the Amplatzer™ Talisman™ Delivery Sheath after the Use-by date stated on the package label.
This device should be used only by physicians who are trained in standard transcatheter techniques. The physician should determine which patients are candidates for procedures that use this device.
Use a hemostasis valve to impede blood backflow during the implant procedure.
PRECAUTIONS
The physician should exercise clinical judgment in situations that involve the use of antithrombotic drugs before, during, and/or after the use of the delivery sheath.
Use caution and rely on imaging guidance when advancing the sheath and dilator to minimize the risk of cardiovascular injury or interference with previously implanted medical devices. Whenever possible, advance the sheath and dilator over a guidewire.
Do not attempt to use a guidewire larger than the maximum diameter specified in the Directions for Use.
Do not use a power injection system to put contrast solution through the sheath.
Remove the dilator and sheath from the patient slowly to prevent an ingress of air.
POTENTIAL ADVERSE EVENTS Potential adverse events that may occur during or after a procedure using this device may include, but are not limited to:
Potential adverse events that may occur during or after a procedure using this delivery sheath may include, but are not limited to: • Allergic reaction/toxic effects due to hypersensitivity to contrast agent, anesthesia, device materials, or drugs used to minimize blood clot formation
Arrhythmia
Arteriovenous fistulae
Bleeding
Cardiac perforation
Cardiac tamponade
Cardiovascular injury
Death
Dissection
Embolism (air, foreign body, and peripheral)
Hematoma
Infection
Myocardial infarction
Pericardial effusion
Thromboembolism
Thrombosis
Vascular access site injury
MAT-2010366 v3.0
DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?
CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.
Precautions
Please be sure to read it.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.
Are you a healthcare professional?
Test
yes
Precautions
Please be sure to read it.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.
Are you a healthcare professional?
Test
[prod, crx3, samplecontent, publish, crx3tar]
test
DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?
CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.
Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.
Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.
The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) of Abbott Medical Japan GK.
The information provided here is not intended to provide information to patients and the general public.