30
CARDIOVASCULAR
hamburger
product photo

REDEFINING POSSIBILITIES IN BTK THERAPY

The Armada™ 14 family is comprised of Armada™ 14 and Armada™ XT PTA catheters. Both offer excellent access and crossing performance for BTK cases. Available in broad size matrix enabling treatment in a wide range of lesions, the Armada™ 14 family was specifically designed to simplify BTK balloon dilatation and to help complete procedures successfully.

EXTENDS YOUR REACH

  • Catheter and balloon design combine flexibility and strength to reach more distal lesions and resist kinking

EXCELLENT LESION ENTRY AND CROSSING*

  • Streamlined tip and a low profile balloon designed to enter and cross difficult lesions

armada-14-balloon-profile-int

RAPID BALLOON DEFLATION

  • Large contrast lumen and novel one-piece tapered catheter designed to provide rapid balloon deflation

armada-14-balloon-deflation-time-int

  • REFERENCES
    Tests performed by and data on file at Abbott.
    *Based on physician preference testing in a clinical setting
    + Product sizes tested: Armada 14: 4.0 x 200 mm x 150 cm, Amphirion Deep: 3.5 / 4.0 x 210 mm x 150 cm, NanoCross: 3.5 / 4.0 x 210 mm x150 cm, SAVVY Long: 4.0 x 220 mm x 120 cm Sterling SL: 4.0 x 120 mm x 150 cm
  • 4Fr sheath compatible, 5Fr guide cath compatible
  • Broad size matrix for a wide range of lesions
  • Nominal pressure: 8 atm
  • RBP: 14 atm
  • 0.014" guide wire compatible

 

Armada™ 90 cm CATHETER

BALLOON DIAMETER (mm)

BALLOON LENGTH (mm)
20 40 60 80 120 200
1.5 A1015-020 A1015-040 - A1015-080 A1015-120 -
2.0 A1020-020 A1020-040 A1020-060 A1020-080 A1020-120 A1020-200
2.5 A1025-020 A1025-040 A1025-060 A1025-080 A1025-120 A1025-200
3.0 A1030-020 A1030-040 A1030-060 A1030-080 A1030-120 A1030-200
4.0 A1040-020 A1040-040 A1040-060 A1040-080 A1040-120 A1040-200

 

Armada™ 150 cm CATHETER

BALLOON DIAMETER (mm)

BALLOON LENGTH (mm)
20 40 60 80 120 200
1.5 A2015-020 A2015-040 - A2015-080 A2015-120 -
2.0 A2020-020 A2020-040 A2020-060 A2020-080 A2020-120 A2020-200
2.5 A2025-020 A2025-040 A2025-060 A2025-080 A2025-120 A2025-200
3.0 A2030-020 A2030-040 A2030-060 A2030-080 A2030-120 A2030-200
4.0 A2040-020 A2040-040 A2040-060 A2040-080 A2040-120 A2040-200

 

Armada™ XT 145 cm CATHETER
BALLOON DIAMETER (mm) BALLOON LENGTH (mm)
12 20
1.2 F2012-012 F2012-020
1.5 F2015-012 F2015-020
2.0 F2020-012 F2020-020

AP2946440-WBO Rev. B

DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?

CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.

True
accessibility
© 2016 Abbott. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.

accessibility

DO YOU WISH TO CONTINUE AND EXIT CARDIOVASCULAR.ABBOTT?

CONTENTS OF THE SITE ARE NOT UNDER THE CONTROL OF ABBOTT.