Proven Success
Demonstrated high success rate in LBBAP procedures.1
Accommodating Solutions
Three unique distal curves and two lengths provide enhanced variability and reach to accommodate various patient anatomy needs.2


Features of CPS Locator™ 3D Catheters
- Accommodates 6F stylet-driven leads, such as the UltiPace™ Pacing Lead, and provides better support with less risk of kinking.3
- The CPS Locator™ 3D is a single-use percutaneous catheter intended to introduce pacing or defibrillator leads.
- Each CPS Locator™ 3D Catheter offers a unique distal curve to accommodate various anatomies.
- The catheter is equipped with a hemostatic valve, and the distal tip is radiopaque to facilitate imaging under fluoroscopy.
- The Agilis HisPro™ Slitter is designed to ensure alignment and protect the lead during catheter slitting.
- Accommodate a 6F lead with a recommended minimum length of 58 cm for the 42 cm catheters and 65 cm for the 45 cm catheters.4
- The catheter has an inner diameter of 7 F, an outer diameter of 9 F, and the dilator is compatible with a 0.035” guidewire.
Ordering Information
Model Number | Model Name | Overall Length (Cm) | Working Length (Cm) | Inner Diameter | Outer Diameter | Minimum Lead Length |
---|---|---|---|---|---|---|
DS2C100-42 | CPS Locator™ 3D, Small | 45 cm | 42 cm | 7 F (2.44 mm) | 9 F (3.00 mm) | 58 cm |
DS2C200-42 | CPS Locator™ 3D, Medium | 45 cm | 42 cm | 7 F (2.44 mm) | 9 F (3.00 mm) | 58 cm |
DS2C300-42 | CPS Locator™ 3D, Large | 45 cm | 42 cm | 7 F (2.44 mm) | 9 F (3.00 mm) | 58 cm |
DS2C200-45 | CPS Locator™ 3D, Medium, Extra Long | 48 cm | 45 cm | 7 F (2.44 mm) | 9 F (3.00 mm) | 65 cm |
DS2C300-45 | CPS Locator™ 3D, Large, Extra Long | 48 cm | 45 cm | 7 F (2.44 mm) | 9 F (3.00 mm) | 65 cm |
References
- Nair, D., & Atwater, B. (2023). Abstracts - 2023 - journal of arrhythmia - wiley online library. Wiley Online Library. https://onlinelibrary.wiley.com/doi/10.1002/joa3.12902
- Abbott. Data on File, Competitive Summary. Item: MAT-2302264 v1.0
- Burri, H., Jastrzebski, M., Cano, O., Curila, K., Pooter, J. de, Huang, W., Israel, C., Joza, J., Romero, J., Vernooy, K., Vijayaraman, P., Whinnett, Z., & Zanon, F. (2023). Ehra clinical consensus statement on conduction system pacing implantation: Executive summary. endorsed by the Asia-Pacific Heart Rhythm Society (APHRS), Canadian heart rhythm society (CHRS) and Latin-American heart rhythm society (LAHRS). Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. https://pubmed.ncbi.nlm.nih.gov/37061850/
- Data on file: 91112329
MAT-2500735 v1.0