XIENCE™ Family of Drug-Eluting Stents

The World's Leading Drug-Eluting Stents (DES), with Unparalleled Clinical Outcomes¹

XIENCE™ Family of Drug-Eluting Stents
Stent DiameterStent LengthPost-Dilatation Limit
8 mm12 mm15 mm18 mm23 mm28 mm33 mm38 mm48 mm
2.0 mm1800200-081800200-121800200-151800200-181800200-231800200-281800200-331800200-38-3.75 mm
2.25 mm1800225-081800225-121800225-151800225-181800225-231800225-281800225-331800225-38-3.75 mm
2.5 mm1800250-081800250-121800250-151800250-181800250-231800250-281800250-331800250-381800250-483.75 mm
2.75 mm1800275-081800275-121800275-151800275-181800275-231800275-281800275-331800275-381800275-483.75 mm
3.0 mm1800300-081800300-121800300-151800300-181800300-231800300-281800300-331800300-381800300-483.75 mm
3.25 mm1800325-081800325-121800325-151800325-181800325-231800325-281800325-331800325-38-3.75 mm
3.5 mm1800350-081800350-121800350-151800350-181800350-231800350-281800350-331800350-381800350-485.75 mm
4.0 mm1800400-081800400-121800400-151800400-181800400-231800400-281800400-331800400-381800400-485.75 mm
4.5 mm-1800450-121800450-151800450-181800450-231800450-281800450-33--5.75 mm
5.0 mm-1800500-121800500-151800500-181800500-231800500-281800500-33--5.75 mm

Product Specifications for XIENCE Skypoint™ Stent

Stent Specifics

Stent DesignMULTI-LINK,
Peak-to-Valley Design
Stent MaterialL-605 Cobalt Chromium
DrugEverolimus
Drug Dose Density100 µg/cm²
PolymerFluorinated Copolymer
Strut Thickness0.0032" (81 µm)
MRI CompatibilityMR Conditional
(see IFU for specific conditions)
Post-DilationSizes
2.00-3.25 mm
3.5-5.0 mm
Post-Dilation Limit
3.75 mm
5.75 mm

 

Delivery System Specifications

Nominal Pressure9 atm for 2.0-2.5 mm;
12 atm for 2.75-5.0 mm
Rated Burst Pressure16 atm for All Diameters
Min. GC/Sheath Diameter5F / 0.056" / 1.42 mm (2.0-4.0 mm, 8-38 mm)
6F / 0.070" / 1.78 mm (2.5-4.0 mm, 48 mm)
6F / 0.070" / 1.78 mm (4.5-5.0 mm, 12-33 mm)
Balloon MaterialPebax 72D
Working Catheter Length145 cm
Shelf Life36 months
Explore Abbott's technologies for your needs.

Explore Abbott's technologies for your needs.

Access personalised education and training

Access personalised education and training

How can we help? Reach Abbott’s fast support here.

How can we help? Reach Abbott’s fast support here.

References

  1. Zanchin C, et al. JACC Cardiovasc Interv. 2019;12(17):1665-1675. Serruys P, et al. N Engl J Med. 2010;363:136-146. Shiomi H, et al. JACC Cardiovasc Interv. 2019;12:637-647. Kufner S, et al. Circulation. 2019:139(3):325-333. Palmerini T, et al. Lancet. 2013;379:1393-1402. Bangalore S, et al. Circulation. 2012;125:2873-2891. Bangalore S, et al. Circ Cardiovasc Interv. 2013;6(6):378-390. Pilgrim T, et al. Lancet. 2014;384:2111-2122. Pilgrim T, et al. Lancet. 2018;392:737-746. Data on file at Abbott.

MAT-2413642 V1.0