CentriMag

Acute Circulatory Support System with Full MagLev Flow Technology

CentriMag Acute Mechanical Circulatory Support System

AMG PMP Oxygenators

Manufactured by Eurosets and distributed by Abbott, the AMG PMP Oxygenators easily integrate with the CentriMag™ Acute Circulatory Support System.

When paired with the Full MagLev™ Flow Technology of the CentriMag™ System, our portfolio of PMP Oxygenators provide a complete ECMO solution for a wide variety of patients.

AMG PMP Oxygenator benefits and features:

  • PMP fibers – for reliable gas exchange performance over duration of use
  • PC Coating – to minimize inflammation1 and thrombosis2
  • Stainless steel heat exchanger – can eliminate risk of any potential contamination
  • Low shear stress – based on shape, fiber orientation, and blood flow path
AMG PMP Oxygenator Sizes
Technical Specifications 
 AMG PMP Adult OxygenatorAMG PMP Pediatric OxygenatorAMG PMP Infant Oxygenator
Maximum Blood Flow Rate7 L/min4 L/min1.5 L/min
Priming Volume220 mL190 mL90 mL
Residual Blood Volume< 200 mL100 mL41 mL
Membrane Surface Area1.81 m²1.35m²0.69m²
Heat Exchanger Surface Area0.08 m²0.08m²0.04m²
Heat Exchanger Performance Factor0.64 at 4 L/min0.64 at 4 L/min0.77 at 1.5 L/min
Max Gas Pressure0.14 PSI (7 mmHg)0.14 PSI (7 mmHg)0.07 PSI (3.5 mmHg)
Venous Inlet and Arterial Outlet3/8" barbed connectors3/8" barbed connectors1/4" barbed connectors
Membrane MaterialPMP with PC coating
Heat Exchanger TypeStainless steel
Max Water Pressure29 PSI (1,500 mmHg)
Max Blood Pressure14.5 PSI (750 mmHg)
Water Inlet and Outlet1/2" Hansen quick couplings
Gas Inlet1/4"
AMG PMP Adult Oxygenator Component Diagram

Blood path fully coated with phosphorylcholine (PC) coating

PC creates a permanent water barrier between blood and the oxygenator surface that minimizes thrombus formation and promotes resistance to bacterial adhesion.3

Phosphorylcholine (PC) coating creates water barrier to minimize thrombosis and reduce bacterial adhesion

Integrated heat-exchanger maximizes heat exchange efficiency

The integrated heat exchanger is:

  • Made of stainless steel for high heat conductivity
  • Non-porous to eliminate risk of bacterial infection or any other potential contamination
  • Corrugated to increase surface area for efficient heat exchange
AMG PMP Oxygenator Integrated Stainless Steel Heat Exchanger

AMG PMP Adult Oxygenator

Watch this video to see the technical features of the AMG PMP Adult Oxygenator.

CentriMag System Animation

Watch this video featuring the CentriMag System and the AMG PMP Adult Oxygenator as a BETTER TOGETHER option for cardiopulmonary support.

Manuals & Technical Resources

Manuals & Technical Resources

Cardiovascular Products

Cardiovascular Products

Customer Service

Customer Service

AMG PMP Oxygenator and Oxygenator Holder manufactured by Eurosets s.r.l., and distributed by Abbott.

ECMO clearance for >6-hour use is indicated for the CentriMag™ Blood Pump to be used with: CentriMag™ Console, CentriMag™ Motor, Mag Monitor, and Flow Probe. ECMO clearance for the CentriMag™ Blood Pump is for adult use only and excludes: CentriMag™ Drainage Cannula and CentriMag™ Return Cannula, PediMag™ Blood Pump and any other pediatric components or accessories.
 

References

  1. Hayward JD, Champ D. Biomembrane surfaces as models for polymer design: the potential for haemocompatibility. Biomaterials. 1984;5:135-142.
  2. Goreish HH, Lewis Al, Rose S, et al. The effect of phosphorylcholine-coated materials on the inflammatory response and fibrous capsule formation: In vitro and in vivo observations. J Biomed Mater Res. 2004;68A:1-9.
  3. Berry JA, Biedlingmaier JF and Whelan PH. In Vitro Resistance to Bacterial Biofilm Formation on Coated Fluroplastic Tympanostomy Tubes. Otolaryngol Head Neck Surg. 2000;123:246-51.

MAT-2207130 v3.0