External Pulse Generator Dual-Chamber (DDD) Model 3085
CARDIOVASCULAR
hamburger
.

External Pulse Generator Dual-Chamber (DDD)

Model 3085

External Pulse Generator Dual-Chamber (DDD)

PRODUCT HIGHLIGHTS

  • Designed for safe and reliable temporary stimulation of the heart in cases of rhythm disturbances and conduction defects, and/or perioperative temporary heart stimulation.
  • An extensive dual-chamber feature set including:

– A full array of mode choices, including a special DDD + AT mode specifically available for bi-atrial stimulation to help avoid atrial fibrillation

– Atrial auto-sensing for automatic adjustment of sensitivity

– Completely adjustable stimulation parameters (voltage and pulse width)

– A wide base rate range of 30-220 ppm for appropriate pacing support for all therapy needs, including those of pediatric patients

– A max tracking rate of 80-230 ppm for maintaining AV synchrony

– A PV delay offset for supporting maximum cardiac output

– Extended PVARP for prevention of retrograde tachycardia

– Crosstalk protection to aid in preventing far-field sensing, which can result in asystole

  • Continuous, independent atrial and ventricular lead surveillance and an audible warning in the event of lead malfunction
  • Rapid atrial pacing rates (up to 1000 ppm) are available for pace-termination of atrial tachycardia

ORDERING INFORMATION

Contents: External pulse generator


Reorder Number Dimensions (H x W x T, cm) Weight (g) Battery
3085 20 x 9.6 x 3.8 490 (includes battery) Standard 9 V, alkaline or lithium


Brief Summary: Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use. Devices depicted may not be available in all countries. Check with your St. Jude Medical representative for product availability in your country.

Indications for Use: The Model 3085 external pulse generator/temporary pacemaker is designed to be used with cardiac stimulation lead systems for temporary atrial, ventricular or A V sequential stimulation. The Model 3085 has applications where such stimulation modes are indicated for therapeutic, rophylactic, or diagnostic purposes. Specific indications include, but are not limited to, the following:

Sick sinus syndrome; Bradycardia with congestive heart failure; Complete heart block; Acute myocardial infarction complicated with heart block; Sinus bradycardia; Cardiac arrest with ventricular systole; Atrial and/or ventricular ectopic arrhythmia; Postoperatively after cardiac surgery; Temporary application during implantation or exchange of a permanent pacemaker. Indication for atrial overdrive stimulation: Supraventricular tachycardia.

Contraindications: There are no contraindications with regards to the use of the Model 3085 for temporary cardiac stimulation for therapy and prevention of arrhythmia. The state of health of the patient, however, can restrict the choice of operational mode and stimulation parameters. For example, a mode of operation with atrial sensing is not suitable or appropriate when atrial fibrillation occurs. This is due to excessive and chaotic frequency of detected fibrillation waves. Overdrive-stimulation therapy must only be used in the atrium. Overdrive-stimulation in the ventricle could cause life threatening ventricular fibrillation

Item GMCRM910EN

Last Updated: January 02, 2019

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

true
accessibility
© 2016 Abbott. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.

accessibility

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?